Jansen GmbH Gebäudetechnik has its address on Geilenkirchener Straße in Gangelt. We size split air conditioning for houses, practices and offices, put the outdoor unit where it stays quiet and stays reachable, and connect it properly.

  • Sizing driven by the rooms, not by the catalogue
  • Outdoor unit on a bracket, damped and accessible
  • Electrical connection by our own trade
Outdoor unit of a split air conditioning system on a light house wall against open sky

Why it stays warm

The heat load is already inside the house

A summer day charges a building. The heat arrives through glass, through the roof and from the equipment in the room, and it does not leave again on its own in the evening. Anyone who only opens a window once it is warm indoors often lets in more heat still.

The top floor

A whole day of warmth stands under the roof. At night the structure gives it back into the rooms, exactly when people are trying to sleep up there.

Large windows facing south and west

Glass lets the sun in and lets heat out only slowly. Without external shading a run of windows heats the room through half the afternoon.

Office, practice, server corner

Computers, equipment, lighting and people give off heat constantly. In a well-insulated room it stays there until somebody moves it out.

Bedrooms

A wall that charged up during the day radiates for half the night. Airing helps only once the air outside is genuinely cooler than the air inside.

A split system takes the heat out of the room and hands it to the outdoor unit, which passes it to the open air. So it does not merely chill the air, it carries the load out of the building. How much capacity that needs is decided by the room, not by the brochure.

Services

What we do on an air conditioning system

From the first assessment to the clean after the season, the system stays in one pair of hands. That is why the pipe run, the connection and the equipment fit one another in the end.

Advice and sizing

We look at the rooms: size, glazed area, orientation, use, and what equipment stands in them. That decides what capacity makes sense and where the indoor unit should hang.

Monosplit and multisplit

One indoor unit on one outdoor unit is the simplest answer. Where several rooms need covering, several indoor units share a common outdoor unit. Which suits better depends on the rooms and on the pipe route.

Outdoor unit and its position

Facade, balcony, terrace or flat roof. We choose the place for airflow, sound, condensate and access, fix it to a wall bracket or a floor frame, and set the unit on vibration mounts.

Pipe route and core drilling

The refrigerant line, the control cable and the condensate drain need a route that bothers nobody later. Core drilling with a fall to the outside, a properly sealed penetration, trunking rather than a visible loop.

Electrical connection

The system takes its supply from the distribution board, with the right protection and proper labelling. That is our own trade and it does not get handed to a second firm.

Servicing and cleaning

Filters, heat exchangers and the condensate route silt up over time. Having that done regularly keeps the output up and keeps smells away.

The metre that matters

The outdoor unit decides how the whole system behaves

Two identical systems can feel completely different if the outdoor unit stands differently. Its position is not a leftover decision at the end of the installation. It is the part of the planning you notice most afterwards.

Outdoor units of an air conditioning system on wall brackets in a white rendered courtyard
Wall brackets on a rendered facade, discharge free to the front.

Air

The unit draws air in and blows it out again. Stand it in a tight recess or hard against a wall and it takes in its own exhaust and works against itself. Free intake and free discharge come before every other wish.

Sound

The fan is audible, even on a quiet machine. We set it away from bedroom windows and away from the boundary, on damping mounts rather than rigidly against a thin wall that would carry the tone into the house.

Condensate

In cooling, water forms at the indoor unit; in heating, at the outdoor unit. Both need a guided route that does not drip onto the footpath and does not turn into a sheet of ice in winter.

Access

What nobody can reach does not get serviced. A position you can get to with a short ladder saves effort at every clean and keeps a later repair affordable.

Fixing and weather

The bracket belongs in load-bearing structure, not in external insulation alone. Add clearance from the ground for snow and leaves, and a spot where the unit does not catch the full midday sun.

Photographs

Outdoor units, facades, balconies

Four situations of the kind found on houses and small commercial buildings. They show what we look at when choosing a position.

Facade Wall mounting on a bracket, discharge into the open.
Balcony Set on a floor frame beside the balustrade.
Side by side Several units on one wall, spaced apart from each other.
Courtyard side A position away from the windows, on firm ground.

Enquiry

Write us a short note about it

A few lines are enough. We call you back, settle the questions on the telephone and arrange a visit when that suits.

Telephone +49 2454 938644
Address Geilenkirchener Straße 65 a, 52538 Gangelt
Fax +49 2454 938645

Which rooms, what kind of building, what matters to you.

Your details go to us alone and are used only to answer this enquiry.

How it runs

From the enquiry to the first cool day

Five steps, in this order. None of them costs you a decision you are not yet able to make.

Enquiry

You ring us or write through the form, with a few sentences about the rooms.

Visit

We look at the rooms, the walls and the possible positions, and measure the pipe route.

Quotation

Equipment, pipe route, electrical connection and effort are set out in writing in a list you can read at your leisure.

Installation

Indoor unit, penetration, pipework, outdoor unit, connection and commissioning. We clear up behind ourselves.

Handover and servicing

You get the controls explained, with the settings that are genuinely used day to day. Regular cleaning follows after that.

Gangelt

Our own address is in Gangelt

That is not a promise about coverage, simply the place where the firm sits. The journey to an appointment, to a correction or to a service is therefore short, and we know how buildings here are put together.

Villages

We work in Gangelt and in its villages:

  • Birgden
  • Breberen
  • Hastenrath
  • Harzelt
  • Kreuzrath
  • Langbroich
  • Mindergangelt
  • Niederbusch
  • Schierwaldenrath
  • Stahe
  • Süsterseel
  • Vinteln

Company address

Jansen GmbH Gebäudetechnik

Geilenkirchener Straße 65 a

52538 Gangelt

+49 2454 938644

info@jansen-elektro.de

Nearby

Equally in the neighbouring municipalities in the Heinsberg district:

  • Geilenkirchen
  • Selfkant
  • Waldfeucht
  • Heinsberg

Questions

What we are asked most often

Can an air conditioning system heat as well?

A split unit can reverse the direction and heat in the milder half of the year. Whether that makes sense for your house, and what it changes about the existing heating, we say after the visit and not before.

How loud is the outdoor unit?

Audible, and how disturbing it is depends more on the position than on the data sheet. Distance from windows and from the boundary, damping mounts under the unit and a fixing that does not carry the tone into the wall achieve more than any figure in a brochure.

Do I need permission?

That depends on the building and on the position. We talk it through before the installation, and we place the unit so that clearance and sound towards the boundary are right from the start.

How many rooms can share one outdoor unit?

On a multisplit system one outdoor unit serves several indoor units. How many is a question of the sizing and of the pipe route, not of a fixed rule.

Does the system have to be serviced?

Yes. Filters and heat exchangers silt up, and the condensate route needs attention too. Regular cleaning keeps the output, saves electricity and prevents smells in the room.

Do you work in the villages as well?

Yes. Birgden, Breberen, Hastenrath, Langbroich, Schierwaldenrath, Stahe, Süsterseel and the remaining villages count as our own town, and so do the neighbouring municipalities in the Heinsberg district.

Sections

Legal notice

Information under section 5 DDG

Jansen GmbH Gebäudetechnik Geilenkirchener Straße 65 a, 52538 Gangelt
Represented by Lennard Jansen

Contact

Telephone +49 2454 938644
Fax +49 2454 938645

Register entry

Register entry Amtsgericht Aachen, HRB 9411 und HRB 9946
VAT DE404851628

Professional details

Professional title Elektrotechnikermeister (erworben in Deutschland)
Awarded in Deutschland
Supervisory chamber Handwerkskammer Aachen, Sandkaulbach 17-21, 52062 Aachen

Liability for content and links

The content of these pages was prepared with care. We cannot, however, warrant that it is correct, complete or up to date. The operator of any external site we link to is always responsible for its content. At the time the link was made no unlawful content was apparent there.

Copyright

The text, structure and design of this page are protected by copyright. Any use beyond the limits of copyright law requires our consent.

Picture credits

The photographs on this page come from the Pexels and Pixabay image archives and are used under their licences. They show no property and no work of this company; they stand as examples for the subject of the section they sit in. The logo is the property of Jansen GmbH Gebäudetechnik.

Dispute resolution

We are neither willing nor obliged to take part in dispute resolution proceedings before a consumer arbitration board.

Privacy

Controller

Jansen GmbH Gebäudetechnik Geilenkirchener Straße 65 a, 52538 Gangelt

Visiting this page

When you open this page your browser transmits the technical data needed to deliver it: IP address, time, requested file, browser type and operating system. That data sits in the server logs, serves secure operation and is not combined with any other source. The legal basis is Art. 6(1)(f) GDPR.

Cookie and local storage

This site sets a single cookie called site_lang. It holds nothing but the language code de, en, pl or ru, applies to this domain, expires after one year and is set with SameSite=Lax. It makes the start page forward you to the language you last chose, if you chose one other than German. It is technically necessary within the meaning of section 25(2)(2) TDDDG and therefore needs no consent. In addition, dismissing the cookie notice writes one entry to your browser local storage so that the notice does not appear on every visit. That entry never leaves your device. This site sets no further cookies, no counting pixels, no statistics and no advertising.

Enquiry form

When you submit the form, your name, telephone number, the email address you chose to give, your message and the path of the page are transmitted to our service provider Olumax, stored there and passed to us. We use the details only to answer your enquiry. The legal basis is Art. 6(1)(b) and (f) GDPR. The details are deleted once they are no longer needed for processing and no statutory retention period stands in the way.

Your rights

You have the right to information, correction, erasure, restriction of processing, data portability and objection. Please write to the address above. You may also complain to a data protection authority, in North Rhine-Westphalia to the State Commissioner for Data Protection and Freedom of Information.

Picture credits

The photographs on this page come from the Pexels and Pixabay image archives. They show no property of this company.

Cookie notice

This site manages with a single cookie. It is called site_lang, holds only the language code, and is set as soon as you choose a language or open a language page.

Name site_lang
Purpose Remembers the chosen language and forwards the start page to it.
Lifetime One year
Kind Technically necessary

Local storage

When you dismiss the cookie notice, the site writes one entry to your browser local storage to record that. That is not a cookie and it is not transmitted. You can delete it at any time in your browser settings.

What is not set here

No statistics, no audience measurement, no advertising networks, no social networks, no third-party maps and no fonts from external servers.